General Maintenance

3606 Rev 11/99

123

Figure 79

2. If the fuel system or a component in the system has been drained

or run out of fuel continue with Step 2, otherwise skip to Step 3.
Ensure that the ignition switch is in the OFF position. Loosen one of
the high pressure connections at the injector. Operate the starter
motor until fuel, free of air, comes out of the pipe connection.
Tighten the connections to 16 lb/ft (22 Nm). The fuel system has
been bled of air.

3. Turn the ignition switch to the START position to start the engine.

OS0731

Vent
Plug

Filter
Head

High

Pressure

Line

Injector

(PERKINS ENGINE)

General Maintenance

3606 Rev 11/99

123

Figure 79

2. If the fuel system or a component in the system has been drained

or run out of fuel continue with Step 2, otherwise skip to Step 3.
Ensure that the ignition switch is in the OFF position. Loosen one of
the high pressure connections at the injector. Operate the starter
motor until fuel, free of air, comes out of the pipe connection.
Tighten the connections to 16 lb/ft (22 Nm). The fuel system has
been bled of air.

3. Turn the ignition switch to the START position to start the engine.