Trigger:holdoff, Trigger:level – GW Instek GDS-200 Series Programming Manual User Manual
Page 99

COMMAND DETAILS
99
Return parameter
Returns the trigger mode.
Example
:TRIGger:MODe NORMal
Sets the trigger mode to normal.
:TRIGger:HOLDoff
Description
Sets or queries the holdoff time.
Syntax
:TRIGger:HOLDoff {
Parameter
Holdoff time
Return parameter
Returns the trigger holdoff time.
Example
:TRIGger:HOLDoff 1.00E-8
Sets the trigger holdoff time to 10ns.
:TRIGger:LEVel
Description
Sets or queries the level.
Syntax
:TRIGger:LEVel {TTL | ECL | SETTO50 |
Related
commands
:TRIGger:TYPe
Parameter
Trigger level value
TTL
Sets the trigger level to TTL.
ECL
Sets the trigger level to ECL.
SETTO50
Sets the trigger level to 50%
Return parameter
Returns the trigger level.
Example1
:TRIGger:LEVel TTL
Sets the trigger to TTL.
Example2
:TRIGger:LEVel 3.30E-1
Sets the trigger level to 330mV/mA.
Set
Query
Set
Query