Gonogo:function, Gonogo:ngcount, Gonogo:ngdefine – GW Instek GDS-200 Series Programming Manual User Manual
Page 119
COMMAND DETAILS
119
Parameter/
OFF
Pauses/Stops the test
Return Parameter ON
Starts the test
Example
:GONogo:EXECute OFF
Turns Go/NoGo off.
:GONogo:FUNCtion
Description
Initializes the Go/NoGo function. This must be
run before any Go/NoGo commands can be used.
Syntax
:GONogo:FUNCtion
:GONogo:NGCount
Description
Returns the Go/NoGo counter.
Syntax
:GONogo:NGCount?
Return parameter Returns a string in the following format “number of
violations,total tests”
Example
:GONogo:NGCount?
> 3,25
Indicates that 3 violations occurred over 25 tests.
:GONogo:NGDefine
Description
Sets the Go/NoGo “When” conditions.
Syntax
:GONogo:NGDefine {EXITs|ENTers|?}
Parameter/
Return Parameter
EXITs
Sets the NoGo condition to when the
input signal exceeds the limit boundary.
ENTers
Sets the NoGo condition to when the
input signal stays within the limit
boundary.
Example
:GONogo:NGDefine EXITs
Sets the Go/NoGo condition to EXITs.
Set
Query
Set
Query