Rotate commands, Rotate – GW Instek GDS-200 Series Programming Manual User Manual
Page 125

COMMAND DETAILS
125
BACKward
Moves to the previous waveform in
memory
Sets the current waveform number.
The waveform number must be equal
to or less than the total number of
waveforms, as returned by the
REPLAY:TOTalnum?
query.
Example
REPLAY:TOTalnum?
8.960E+02
REPLAY:CURRent 100
REPLAY:TOTalnum?
1.000E+02
Indicates that there are a total of 896 waveforms.
Set the current waveform to #100. The return value
(100) indicates that the current waveform is #100.
Rotate Commands
The rotate function sets the screen orientation.
:ROTATE ....................................................................125
:ROTATE
Description
Sets or queries the screen orientation.
Syntax
:ROTATE { PORTrait | LANDscape | 0 | 1 | ? }
Parameter/Return
parameter
PORTrait / 0
PORTrait
LANDscape / 1
LANDscape
Set