:MEASure:RPReshoot

Description

Returns rising preshoot over the entire waveform
in percentage.

Syntax

:MEASure:RPReshoot?

Related
Commands

:MEASure:SOURce

Return parameter

Returns the rising preshoot.

Chan Off

Indicates the source channel is not
activated.

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH1
:MEASure:RPReshoot?
2.13E-2
Selects Channel 1, and then measures the rise
preshoot.

:MEASure:FPReshoot

Description

Returns fall preshoot amplitude.

Syntax

:MEASure:FPReshoot?

Related
Commands

:MEASure:SOURce

Returns

Returns the fall preshoot as .

Return parameter

Returns the fall preshoot as a percentage.