Measurement:statistics:mode, Measurement:statistics – GW Instek GDS-200 Series Programming Manual User Manual
Page 85

COMMAND DETAILS
85
Example
:MEASUrement:MEAS3:SOUrce1 CH1
:MEASUrement:MEAS3:TYPe PK2PK
:MEASUrement:STATIstics:MODe ON
:MEASUrement:MEAS3:MINImum?
1.600E-02
Returns the minimum measurement result for
measurement number 3.
:MEASUrement:STATIstics:MODe
Description
Puts the statics measurement results on the display
or queries whether the statistics are displayed. This
is the equivalent of showing the automatic
measurements in the expanded mode (statistics
mode on) condensed mode (statistics mode off).
Syntax
:MEASUrement:STATIstics:MODe {OFF | ON | ?}
Related
commands
:MEASUrement:STATIstics
Parameter/
Return parameter
ON
Display the statistics on the screen.
OFF
Remove the statistics from the screen
Example
:MEASUrement:STATIstics:MODe ON
Displays statistics on the screen.
:MEASUrement:STATIstics
Description
Resets the statics calculations. This command will
clear all the currently accumulated measurements.
Syntax
:MEASUrement:STATIstics {RESET}
Set
Query
Set