Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual
Page 946
916
Fabric OS Command Reference
53-1003131-01
portShow
2
1/22 - High 2d23h11m 0.00 0.00 0.00 0.00
1/22 - Medium 2d23h11m 0.00 0.00 0.00 0.00
1/22 - Low 2d23h11m 0.00 0.00 0.00 0.00
1/22 0 1/xge0 - 2d23h11m 0.00 0.00 0.00 0.00
1/22 0 1/xge0 F-Class 2d23h11m 0.00 0.00 0.00 0.00
1/22 0 1/xge0 Medium 2d23h11m 0.00 0.00 0.00 0.00
1/22 0 1/xge0 Low 2d23h11m 0.00 0.00 0.00 0.00
1/22 1 1/xge1 - 2d23h11m 0.00 0.00 0.00 0.00
1/22 1 1/xge1 F-Class 2d23h11m 0.00 0.00 0.00 0.00
1/22 1 1/xge1 High 2d23h11m 0.00 0.00 0.00 0.00
1/22 1 1/xge1 Medium 2d23h11m 0.00 0.00 0.00 0.00
1/22 1 1/xge1 Low 2d23h11m 0.00 0.00 0.00 0.00
-------------------------------------------------------------------
To display the IP addresses configured for the circuits on the Brocade FX8-24:
switch:admin> portshow fciptunnel --circuit --config
Tunnel Circuit AdminSt Flags Local IP Remote Ip
-----------------------------------------------------------------------------
---
8/12 - Enabled -------
8/12 0 8/xge1 Enabled ---4--s 192.168.0.16 192.168.0.116
8/24 - Enabled -------
8/24 0 8/xge0 Enabled ---4--s 192.168.0.11 192.168.0.111
-----------------------------------------------------------------------------
---
Flags (tunnel): c=compression m=moderate compression a=aggressive compression
A=Auto compression f=fastwrite t=Tapepipelining F=FICON
T=TPerf i=IPSec l=IPSec Legacy
(circuit): s=sack v=VLAN Tagged x=crossport 4=IPv4 6=IPv6
L=Listener I=Initiator
To display all FCIP circuits on the Brocade FX8-24:
switch:admin> portshow fcipcircuit all
------------------------------------------------------------------------
Tunnel Circuit OpStatus Flags Uptime TxMBps RxMBps ConnCnt CommRt Met/G
------------------------------------------------------------------------
1/12 0 1/xge1 Up ---4--s 3d2m 000 0.00 1 2500/2500 0/-
1/12 1 1/xge0 Up ---4-xs 3d2m 0.00 0.00 1 2500/2500 1/-
1/21 0 1/xge1 Up ---4--s 3d1m 0.00 0.00 1 2500/2500 0/-
1/21 1 1/xge0 Up ---4-xs 3d2m 0.00 0.00 1 2500/2500 1/-
1/22 0 1/xge0 Up ---4--s 3d1m 0.00 0.00 1 2500/2500 0/-
1/22 1 1/xge1 Up ---4-xs 3d2m 0.00 0.00 1 2500/2500 1/-
1/31 0 1/xge0 Up ---4--s 3d2m 0.00 0.00 1 2500/2500 0/-
1/31 1 1/xge1 Up ---4-xs 3d2m 0.00 0.00 1 2500/2500 1/-
------------------------------------------------------------------------
Flags:circuit:s=sack v=VLAN Tagged x=crossport 4=IPv4 6=IPv6
T=Test(CPerf) L=Listener I=Initiator
To display the details for all FCIP circuits on the Brocade FX8-24 (Note that both circuits are configured
as initiators):
switch:admin> portshow fcipcircuit all --detail
-------------------------------------------
Circuit ID: 1/12.0
Circuit Num: 0
Admin Status: Enabled
Oper Status: Up
Connection Type: Initiator