Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual
Page 199
Fabric OS Command Reference
169
53-1003131-01
configureChassis
2
1
Sets the CS_CTL to VC mapping to support three CS_CTL values: 1 (low
priority), 2 (medium priority), and 3 (high priority). Each CS_CTL value can
map to more than one VC depending on the underlying support from ASIC.
This is the auto mode. For more information about CS_CTL-based frame
prioritization, refer to the Fabric OS Administrator's Guide.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
None
EXAMPLES
To enable signature validation for downloading firmware:
switch:admin> configurechassis
Configure...
cfgload attributes (yes, y, no, n): [no] y
Enforce secure config Upload/Download (yes, y, no, n): [no]
Enforce signature validation for firmware (yes, y, no, n): [no]y
Add Suffix to the uploaded file name (yes, y, no, n): [no]
Do you want to enable auto firmwaresync (yes, y, no, n): [no]
Custom attributes (yes, y, no, n): [no]
system attributes (yes, y, no, n): [no]
fos attributes (yes, y, no, n): [no]
To add a suffix to the uploaded file name:
switch:admin> configurechassis
Configure...
cfgload attributes (yes, y, no, n): [no] y
Enforce secure config Upload/Download (yes, y, no, n): [no]
Enforce signature validation for firmware (yes, y, no, n): [no]
Add Suffix to the uploaded file name (yes, y, no, n): [no] y
Do you want to enable auto firmwaresync (yes, y, no, n): [no]
Custom attributes (yes, y, no, n): [no]
system attributes (yes, y, no, n): [no]