beautypg.com

Portcfgdefault – Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual

Page 759

background image

Fabric OS Command Reference

729

53-1003131-01

portCfgDefault

2

portCfgDefault

Resets the port configuration to factory default value.

SYNOPSIS

portcfgdefault [slot/][ge]port

DESCRIPTION

Use this command to reset all configuration values on a specified port to their factory defaults. This
command persistently disables ports capable of routing, which is the factory default value. Use the
portCfgShow command to display the port configuration.

This command does not change the state of a port. To change the state of an E_Port, use either
switchDisable/switchEnable or portDisable/portEnable.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

This command has the following operands:

slot

For bladed systems only, specifies the slot number of the port to be reset, followed
by a slash (/).

port

Specifies the number of the port to be reset, relative to its slot for bladed systems.
Use switchShow to list of valid ports.

EXAMPLES

To reset a port to factory defaults:

switch:admin> portcfgdefault 1/3

To reset a GbE port to factory defaults:

switch:admin> portcfgdefault 8/ge1

SEE ALSO

portCfgEport

,

portCfgGport

,

portCfgLongDistance

,

portCfgLport

,

portCfgPersistentDisable

,

portCfgPersistentEnable

,

portCfgShow

,

portCfgSpeed

,

portCfgTrunkPort