background image

Fabric OS Command Reference

239

53-1003131-01

diagClearError

2

diagClearError

Clears the diagnostics failure status.

SYNOPSIS

diagclearerror [[--slot] slot] -all

DESCRIPTION

Use this command to clear the diagnostics failure status. When used without operands, this command
clears all port failure flags.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

This command has the following operand:

--slot slot

Specify the slot on which to clear the diagnostics failure status. The default is set
to 0 and designed to operate on fixed-port-count products.

-all

If specified, all blades clear.

EXAMPLES

To clear the diag software flag:

switch:admin> diagclearerror --slot 8

ERROR: DIAG CLEARERR

Diagnostics Errors Cleared, port: 8/31

Err# 0120041 081F

SEE ALSO

None