Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual
Page 1149
Fabric OS Command Reference
1119
53-1003131-01
switchShow
2
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
On the Brocade FCoE10-24 blade, the Proto column identifies the FCoE ports of the switch. For all FCoE
ports, the speed is 10 Gbps. The default configuration of an FCoE port is an F_Port configuration. After a
successful reboot switchShow displays all FCoE ports as online. For each FCoE port, the FCoE
controller WWN is shown. FCoE ports are not configurable with the Fabric OS port commands. Use the
FCoE commands instead.
If a port is configured as a long distance port, the long distance level is displayed in the format of Lx,
where x represents the long distance level number. See portCfgLongDistance for the level description.
When a port is configured as an N_Port and is online, switchShow displays its type as an N_Port. Also,
switchShow displays the WWN of the border switch attached to this N_Port as a 24-bit Port Identifier
assigned to this port by the enterprise fabric.
In an AD context, if one of the L_Ports or NPIV Ports is a part of the current AD, the complete device
information attached to the port is displayed.
OPERANDS
This command has the following operands:
-slot slot
Displays blade information. You can specify this operand with -portname or
-qsfp.
-portname
Displays the name for each port on the switch. The port name is set by the
portName command.
-qsfp
Displays the output of the switchShow command with a QSFP column added. If a
QSFP is installed on the port, the QSFP number is displayed for the port. This
number corresponds to the physical QSFP number that can be found on the front
of each Core Blade. A double dash (--) indicates that QSFP is not supported on
that blade.
-portcount
Displays the number of ports on the switch. This operand is exclusive.
EXAMPLES
To display the port count:
switch:admin> switchshow -portcount
FC ports = 198, GE ports = 12
To display a QoS-capable Core Access Gateway with online AoQ F_Ports and N_Ports:
switch:admin> switchshow
switchName: Spirit_125
switchType: 66.1
switchState: Online
switchMode: Access Gateway Mode
switchWwn: 10:00:00:05:1e:85:95:d0
switchBeacon: OFF
FC Router: OFF
FC Router BB Fabric ID: 1
Area Port Media Speed State Proto
=====================================
0 0 -- N8 No_Module FC
1 1 -- N8 No_Module FC
2 2 -- N8 No_Module FC
3 3 -- N8 No_Module FC