beautypg.com

Portdporttest – Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual

Page 852

background image

822

Fabric OS Command Reference

53-1003131-01

portDPortTest

2

portDPortTest

Initiates or terminates a D_Port test, or displays D_Port test results.

SYNOPSIS

portdporttest --start | --setarg [-nframes number | -time time]

[-framesizesize] [-pattern pat_name |

-payload payload_pattern] [-fec] [-cr] [slot/]port_list

portdporttest --stop [slot/]port_list

portdporttest --restart [slot/]port_list

portdporttest --show [slot/]port_list | -detail [slot/]port_list | all

portdporttest --exit [slot/]port_list

portdporttest --help

DESCRIPTION

Use this command to manually terminate, re-initiate test, or stop test on a diagnostic port (D_Port). The
portdporttest --show command dispalys the result of the D_Port tests. The port must be configured as a
D_Port and physically connected to a second D_Port on a remote switch. Refer to the portCfgDPort
command for more information. The portdporttest --start command only needs to be issued on one end
of the link.

The D_Port test performs the following diagnostics:

An electrical loopback test (supported only on 16Gb SFPs capable of electrical loopback)

An optical loopback test (supported only on 16Gb SFPs capable of optical loopback)

A link traffic test

A link distance measurement

Use the --setarg option to set the test parameters and exit. Use the --restart option to restart the test
with the already configured parameters.

Use the --show option with a port operand to display the test status for the specified ports at any time
during the test or after the diagnostics has completed. The command output includes the following
information for each configured D_Port:

Slot

The slot number on the local side of the link.

Port

The port number on the local side of the link

Remote WWNN

The world wide node name of the switch on the remote side of the link.

Remote WWPN

The world wide port name of the Host Bus Adapter (HBA) or device port on the
remote side of the link.

Remote port index

The port number on the remote side of the link

Mode

The testing mode: Automatic (initiated due to port online event) or Manual
(manually restarted using this command).