Fabric OS Command Reference

535

53-1003131-01

islShow

2

To display interswitch links with D_Port enabled:

switch:user> islshow

1: 24->343 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:

16.000G CR_RECOV FEC

2: 25->341 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:

16.000G CR_RECOV FEC

3: 26-> 95 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:

16.000G CR_RECOV FEC

4: 27->340 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:

16.000G CR_RECOV FEC

5: 29->166 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:

16.000G CR_RECOV FEC

6: 30->165 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX sp: 16.000G bw:

16.000G QOS CR_RECOV FEC

To display the neighbor switch WWN for the segmented ISLs during ELP and post ELP phase:

switch:user> islshow

[...]

1:9-> 2 10:00:00:05:1e:a3:00:59 (incompatible)

[...]

SEE ALSO

switchShow

,

trunkShow