Brocade Fabric OS Command Reference (Supporting Fabric OS v7.3.0) User Manual
Page 915
Fabric OS Command Reference
885
53-1003131-01
portShow
2
portFlags
A bit map of port status flags, including information on the type of port, whether it
is fully online, and whether logins have been accepted. The port flags display
ENCRYPT if the port has been enabled for encryption. The port flags display
COMPRESS if the port has been enabled for compression. The port flags display
D_PORT if the port has been enabled as a diagnostic port. The port flags display
FLOGI_LOGO if the base device logs out and at least one NPIV is online.
portType
The port's type and revision numbers.
POD Port
Port on Demand License status.
portState
The port's SNMP state:
Online
Up and running.
Offline
Not online, see portPhys for more detail.
Testing
Running diagnostics.
Faulty
Failed diagnostics.
Persistently Disabled
Persistently disabled.
Protocol
Protocol used by the port: FC or FCoE.
portPhys
The port's physical state:
No_Card
No interface card present.
No_Module
No module (GBIC or other) present.
No_Light
Module is not receiving light (Condor 2 ports only).
No_SigDet
No signal detected; displays when a quad small form-factor pluggables (QSFPs)
is installed without cables).
Mod_Inv
Incompatible vendor or module speed mismatch.
No_Sync
Receiving light but out of sync.
In_Sync
Receiving light and in sync.
Laser_Flt
Module is signaling a laser fault.
Port_Flt
Port marked faulty.
Diag_Flt
Port failed diagnostics.