Series f4 modbus registers, Parameters sorted alphabetically – Watlow Series F4S/D User Manual
Page 78

103
% Power Output 1A, Status
r
0 to 100
(expressed in %)
107
% Power Output 1B, Status
r
0 to 100
(expressed in %)
111
% Power Output 2A, Status
r
0 to 100
(expressed in %)
115
% Power Output 2B, Status
r
0 to 100
(expressed in %)
102
Alarm 1, Status
r
106
Alarm 2, Status
r
303
Alarm High Deviation, Alarm 1, Value
r/w
1 to 30000
322
Alarm High Deviation, Alarm 2, Value
r/w
1 to 30000
303
Alarm High Set Point, Alarm 1, Value
r/w
322
Alarm High Set Point, Alarm 2, Value
r/w
703
Alarm Hysteresis, Alarm Output 1
r/w
1 to 30000
720
Alarm Hysteresis, Alarm Output 2
r/w
1 to 30000
704
Alarm Latching, Alarm Output 1
r/w
0
Alarm Self-clears
1
Alarm Latches
721
Alarm Latching, Alarm Output 2
r/w
0
Alarm Self-clears
1
Alarm Latches
707
Alarm Logic, Alarm Output 1
r/w
0
Open on Alarm
1
Close on Alarm
724
Alarm Logic, Alarm Output 2
r/w
0
Open on Alarm
1
Close on Alarm
302
Alarm Low Deviation, Alarm 1, Value
r/w
-19999 to -1
321
Alarm Low Deviation, Alarm 2, Value
r/w
-19999 to -1
302
Alarm Low Set Point, Alarm 1, Value
r/w
321
Alarm Low Set Point, Alarm 2, Value
r/w
708
Alarm Messages, Alarm Output 1
r/w
0
Yes on Main Page
1
No
725
Alarm Messages, Alarm Output 2
r/w
0
Yes on Main Page
1
No
1308
Alarm Set Point, Lockout
r/w
0
Full Access
1
Read Only
2
Password
3
Hidden
706
Alarm Sides, Alarm Output 1
r/w
0
Both
1
Low
2
High
723
Alarm Sides, Alarm Output 2
r/w
0
Both
1
Low
2
High
705
Alarm Silencing, Alarm Output 1
r/w
0
No
1
Yes
722
Alarm Silencing, Alarm Output 2
r/w
0
No
1
Yes
716
Alarm Source, Alarm Output 1
r/w
0
Input 1
1
Input 2
2
Input 3
733
Alarm Source, Alarm Output 2
r/w
0
Input 1
1
Input 2
2
Input 3
702
Alarm Type, Alarm Output 1
r/w
0
Off
1
Process
2
Deviation
719
Alarm Type, Alarm Output 2
r/w
0
Off
1
Process
2
Deviation
1902
Altitude, Analog Input 2
r/w
0
0 to 2499 ft
1
2500 to 4999 ft
2
5000 ft and above
606
Analog Input 1 Decimal Point
r/w
0
0
1
00
2
000
3
0000
616
Analog Input 2 Decimal Point
r/w
0
0
1
00
2
000
3
0000
626
Analog Input 3 Decimal Point
r/w
0
0
1
00
2
000
3
0000
836
Analog Range, Retransmit Output 1
r/w
0
4 to 20mA
1
0 to 20mA
2
0 to 5V
3
1 to 5V
4
1 to 10V
837
Analog Range, Retransmit Output 2
r/w
0
4 to 20mA
1
0 to 20mA
2
0 to 5V
3
1 to 5V
4
1 to 10V
305
Autotune Channel 1
r/w
0
Tune Off
1
PID Set 1
2
PID Set 2
3
PID Set 3
4
PID Set 4
5
PID Set 5
324
Autotune Channel 2
r/w
0
Tune Off
1
PID Set 6
2
PID Set 7
3
PID Set 8
4
PID Set 9
5
PID Set 10
343
Autotune Cascade
r/w
0
Tune Off
1
PID Set 1
2
PID Set 2
3
PID Set 3
4
PID Set 4
5
PID Set 5
7 . 2
■
C o m m u n i c a t i o n s
Wa t l o w S e r i e s F 4 S / D
Series F4 Modbus Registers
Parameters Sorted Alphabetically
Register numbers listed are relative values. To convert to absolute values, add 40001. Registers for
profiling parameters are in a separate section at the end of this list, followed by a list of all Mod-
bus registers in numerical order. For more information about parameters, see the Index.