Diagnostic menu parameter table (factory page) – Watlow Series F4S/D User Manual
Page 117
![background image](/manuals/359283/117/background.png)
Wa t l o w S e r i e s F 4 S / D
D i a g n o s t i c s
■
1 0 . 3
✔ NOTE: For more information about how parameter settings
affect the controller’s operation, see the Features Chapter.
Diagnostic Menu Parameter Table (Factory Page)
Modbus
Register
Range
read/write
Conditions for
Parameter
Description
(Modbus Value)
Default
[I/O, Set, Ch]
Parameters to Appear
Active: Always.
1515 r
xx (xx)
Line Freq
Display the ac line
frequency in hertz.
Active: Always.
1531 r
xx.x (xxx)
CJC2 Temp
Cold junction com-
pensation for analog
input 2. Reads the
ambient temperature
of the controller.
Active: Always.
1500 r
xx.x (xxx)
CJC1 Temp
Cold junction com-
pensation for analog
input 1. Reads the
ambient temperature
of the controller.
Active: Always.
1532 r
HHHH
CJC2 AtoD
Factory use only.
Active: Always.
1501 r
HHHH
CJC1 AtoD
Factory use only.
Active: Always.
1506 r
HHHH
In3 AtoD
Factory use only.
Active: Always.
1505 r
HHHH
In2 AtoD
Factory use only.
Active: Always.
1504 r
HHHH
In1 AtoD
Factory use only.
Active: Always.
21 r
Process (4)
None (0)
Retrans2
Displays the retrans-
mit 2 option.
Active: Always.
20 r
Process (4)
None (0)
Retrans1
Displays the retrans-
mit 1 option.