F4 Modbus Applications: Naming a Profile

Profiles without custom-written names are referred to by their numbers (Profile 1, Profile 2,

etc.). Follow this procedure to customize the profile name, using ASCII-equivalent decimal

codes (in the column labeled “Dec” in the chart below).

Renaming a Profile - F4

via Modbus Communication

Write to Modbus Register

xxxx=File Name Character

using decimal equivalent

Next Modbus Register

No

Next

Char

Have 10

characters

been

written?

Done

Modbus
Register

File #

xxxx=
3500 - 3509

1

3510 - 3519

2

3520 - 3529

3

3530 - 3539

4

3540 - 3549

5

3550 - 3559

6

3560 - 3569

7

3570 - 3579

8

3580 - 3589

9

3590 - 3599

10

3600 - 3609

11

3610 - 3619

12

3620 - 3629

13

3630 - 3639

14

3640 - 3649

15

3650 - 3659

16

3660 - 3669

17

3670 - 3679

18

3680 - 3689

19

3690 - 3699

20

3700 - 3709

21

3710 - 3719

22

3720 - 3729

23

3730 - 3739

24

3740 - 3749

25

3750 - 3759

26

3760 - 3769

27

3770 - 3779

28

3780 - 3789

29

3790 - 3799

30

3800 - 3809

31

3810 - 3819

32

3820 - 3829

33

3830 - 3839

34

3840 - 3849

35

3850 - 3859

36

3860 - 3869

37

3870 - 3879

38

3880 - 3889

39

3890 - 3899

40

Determine file number to
Name - See list on right

File Name
Character

Dec

blank

32

0

48

1

49

2

50

3

51

4

52

5

53

6

54

7

55

8

56

9

57

A

65

B

66

C

67

D

68

E

69

F

70

G

71

H

72

I

73

J

74

K

75

L

76

M

77

N

78

O

79

P

80

Q

81

R

82

S

83

T

84

U

85

V

86

W

87

X

88

Y

89

Z

90

Note: There are ten

Modbus Registers for

each profile name.

Save Changes

Write Modbus Register

25=0

Yes