7 . 2 5
F4 Modbus Applications: Naming a Profile
Profiles without custom-written names are referred to by their numbers (Profile 1, Profile 2,
etc.). Follow this procedure to customize the profile name, using ASCII-equivalent decimal
codes (in the column labeled “Dec” in the chart below).
Renaming a Profile - F4
via Modbus Communication
Write to Modbus Register
xxxx=File Name Character
using decimal equivalent
Next Modbus Register
No
Next
Char
Have 10
characters
been
written?
Done
Modbus
Register
File #
xxxx=
3500 - 3509
1
3510 - 3519
2
3520 - 3529
3
3530 - 3539
4
3540 - 3549
5
3550 - 3559
6
3560 - 3569
7
3570 - 3579
8
3580 - 3589
9
3590 - 3599
10
3600 - 3609
11
3610 - 3619
12
3620 - 3629
13
3630 - 3639
14
3640 - 3649
15
3650 - 3659
16
3660 - 3669
17
3670 - 3679
18
3680 - 3689
19
3690 - 3699
20
3700 - 3709
21
3710 - 3719
22
3720 - 3729
23
3730 - 3739
24
3740 - 3749
25
3750 - 3759
26
3760 - 3769
27
3770 - 3779
28
3780 - 3789
29
3790 - 3799
30
3800 - 3809
31
3810 - 3819
32
3820 - 3829
33
3830 - 3839
34
3840 - 3849
35
3850 - 3859
36
3860 - 3869
37
3870 - 3879
38
3880 - 3889
39
3890 - 3899
40
Determine file number to
Name - See list on right
File Name
Character
Dec
blank
32
0
48
1
49
2
50
3
51
4
52
5
53
6
54
7
55
8
56
9
57
A
65
B
66
C
67
D
68
E
69
F
70
G
71
H
72
I
73
J
74
K
75
L
76
M
77
N
78
O
79
P
80
Q
81
R
82
S
83
T
84
U
85
V
86
W
87
X
88
Y
89
Z
90
Note: There are ten
Modbus Registers for
each profile name.
Save Changes
Write Modbus Register
25=0
Yes