beautypg.com

Profiles page parameter table, Idle – Watlow Series F4S/D User Manual

Page 48

background image

Active if controller is set to Dual

Channel Ramping (Channel 2).

4062 r/w

75 (75)

Set Point 2 Low Limit

to Set Point 2 High

Limit

Enter Channel 2 Idle Set

Point

Select the channel 2

set point to be main-

tained after the pro-

file ends.

Active: Always (Channel 1).

4061 r/w

75 (75)

Set Point 1 Low Limit

to Set Point 1 High

Limit

Enter Channel 1 Idle Set

Point

Select the channel 1

set point to be main-

tained after the pro-

file ends.

Main > Profiles > Edit Profile > Profile x (1 to 40) > Edit Step / Step x (1 to 256) > Step > End > Idle

Idle

NOTE: Two sets of Modbus registers contain profile informa-
tion: In edit mode, the number of the profile being edited is at
4000, and the number of the step being edited is at 4001. When
the profile is running, the number of the profile being run is at
4100, and the number of the step being run is at 4101. All run
addresses are read only.

4 . 1 6

P r o f i l e P r o g r a m m i n g

Wa t l o w S e r i e s F 4 S / D

Profiles Page Parameter Table

Modbus

Register

Range

read/write

Conditions for

Parameter

Description

(Modbus Value)

Default

[I/O, Set, Ch]

Parameters to Appear

NOTE: Press the Information Key ˆ for task-related tips.