Setup Page

see Chapter 5

System

Guar. Soak Band1
Guar. Soak Band2
Current Time
Current Date
PID Units
°F or °C
Show °F or °C
Ch1 Autotune SP
Ch2 Autotune SP
Input 1 Fail
Input 2 Fail
Open Loop Ch1
Open Loop Ch2
Power-Out Time
Power-Out Action

Analog Input x (1 to 3)

Sensor
Type
Decimal
Altitude
Units
Scale Low
Scale High
Choose Scaling
Ch2 Output Disable?
Enter In1 Temp Low
Enter In1 Temp High
SP Low Limit
SP High Limit
Calibration Offset
Filter Time
Error Latch
Cascade

Digital Input x (1 to 4)

Name
Function
Condition

Control Output x (1A, 1B,

2A, or 2B)

Function

Cycle Time
Process
Hi Power Limit
Lo Power Limit

Alarm Output x (1 and 2)

Name
Alarm Type
Alarm Source
Latching
Silencing
Alarm Hysteresis
Alarm Sides
Alarm Logic
Alarm Messages

Retransmit Output x (1 and 2)

Retransmit Source
Analog Range
Low Scale
High Scale
Scale Offset

Digital Output x (1 to 8)

Name
Function

Off
Event Output
Boost Heat

Boost %Power
Boost Delay Time

Boost Cool

Boost %Power
Boost Delay Time

Compressor

Compressor On %Power
Compressor Off %Power
Compressor On Delay
Compressor Off Delay

Communications (see Chapter 7)

Baud Rate
Address

Custom Main Page P x

(Parameter 1 to 16)

Factory Page

see Chapters 8, 9, 10

Set Lockout

Set Point
Oper.Autotune PID
Oper. Edit PID
Oper. Alarm SP
Profile
Setup
Factory
Change Password
Clear Locks

Diagnostic

Model
Mfg Date
Serial #
Software #
Revision
Inx (1 to 3)
Out x (1A, 1B, 2A, or 2B)
Retrans x (1 or 2)
In x (1 to 3) AtoD
CJC x (1 or 2) AtoD
CJC x (1 or 2) Temp
Line Freq

Test

Test Outputs
Display Test
Full Defaults

Calibration

Calibrate Input x (1 to 3)
Calibrate Output x (1A,

1B, 2A, or 2B)

Calibrate Rexmit x (1 or

2)

Restore In x (1 to 3) Cal

NOTE:
Some parameters may not appear,
depending on the controller model
and how it is configured. Some
menus may not appear if the
controller has already been installed
in equipment and the manufacturer
has locked out portions of the
software.

F

4

1

2

i

1B

1B

2A

2A

2B

2B

1A

1A

Upper Display
process information

Output status

Alarm status

Communications
status

Profile Light
run/hold
status

Lower Display
alarm, error, status information
and access to software

Information Key
toggles to tips and
definitions about the
chosen parameter

Move up,
increase

Move down,
decrease

Next

Back

Scroll up or down

Cursor

Profile Key
run, hold,
resume,
terminate
profiles

W a t l o w S e r i e s F 4

A p p e n d i x

A . 1 7