Setup Page
see Chapter 5
System
Guar. Soak Band1
Guar. Soak Band2
Current Time
Current Date
PID Units
°F or °C
Show °F or °C
Ch1 Autotune SP
Ch2 Autotune SP
Input 1 Fail
Input 2 Fail
Open Loop Ch1
Open Loop Ch2
Power-Out Time
Power-Out Action
Analog Input x (1 to 3)
Sensor
Type
Decimal
Altitude
Units
Scale Low
Scale High
Choose Scaling
Ch2 Output Disable?
Enter In1 Temp Low
Enter In1 Temp High
SP Low Limit
SP High Limit
Calibration Offset
Filter Time
Error Latch
Cascade
Digital Input x (1 to 4)
Name
Function
Condition
Control Output x (1A, 1B,
2A, or 2B)
Function
Cycle Time
Process
Hi Power Limit
Lo Power Limit
Alarm Output x (1 and 2)
Name
Alarm Type
Alarm Source
Latching
Silencing
Alarm Hysteresis
Alarm Sides
Alarm Logic
Alarm Messages
Retransmit Output x (1 and 2)
Retransmit Source
Analog Range
Low Scale
High Scale
Scale Offset
Digital Output x (1 to 8)
Name
Function
Off
Event Output
Boost Heat
Boost %Power
Boost Delay Time
Boost Cool
Boost %Power
Boost Delay Time
Compressor
Compressor On %Power
Compressor Off %Power
Compressor On Delay
Compressor Off Delay
Communications (see Chapter 7)
Baud Rate
Address
Custom Main Page P x
(Parameter 1 to 16)
Factory Page
see Chapters 8, 9, 10
Set Lockout
Set Point
Oper.Autotune PID
Oper. Edit PID
Oper. Alarm SP
Profile
Setup
Factory
Change Password
Clear Locks
Diagnostic
Model
Mfg Date
Serial #
Software #
Revision
Inx (1 to 3)
Out x (1A, 1B, 2A, or 2B)
Retrans x (1 or 2)
In x (1 to 3) AtoD
CJC x (1 or 2) AtoD
CJC x (1 or 2) Temp
Line Freq
Test
Test Outputs
Display Test
Full Defaults
Calibration
Calibrate Input x (1 to 3)
Calibrate Output x (1A,
1B, 2A, or 2B)
Calibrate Rexmit x (1 or
2)
Restore In x (1 to 3) Cal
✔ NOTE:
Some parameters may not appear,
depending on the controller model
and how it is configured. Some
menus may not appear if the
controller has already been installed
in equipment and the manufacturer
has locked out portions of the
software.
F
4
1
2
i
1B
1B
2A
2A
2B
2B
1A
1A
Upper Display
process information
Output status
Alarm status
Communications
status
Profile Light
run/hold
status
Lower Display
alarm, error, status information
and access to software
Information Key
toggles to tips and
definitions about the
chosen parameter
Move up,
increase
Move down,
decrease
Next
Back
Scroll up or down
Cursor
Profile Key
run, hold,
resume,
terminate
profiles
W a t l o w S e r i e s F 4
A p p e n d i x
■
A . 1 7