CPC400 Series User’s Guide

Chapter 2: Installation

Doc. 0600-2900-2000

Watlow Anafaze

37

Functions Activated by Digital Inputs

Use digital inputs to activate the following functions:

Load a job that is stored in controller memory. See
BCD Job Load on page 97.

Change all loops to manual mode at specified output
levels. See Mode Override on page 99.

Enable thermocouple short detection. See Thermocou-
ple Short Alarm on page 101
.

Restore automatic control after a failed sensor has been
repaired. See Restore Automatic Mode on page 114.

TB18 Connections

Table 2.5

TB18 Connections

1

The indicated outputs are dedicated for control when enabled in the

loop setup. If one or both of the outputs are disabled for a loop, then the
corresponding digital outputs become available for alarms or program-
mable logic.

2

If you install a Watlow Anafaze Serial DAC, the CPC400 series control-

ler uses digital output 34 for a clock line. You cannot use output 34 for
anything else if a Serial DAC is installed.

Control Output

1

Terminal

Function

CPC404

CPC408

1

+5V

Î

(dc)

2

CTRL COM

3

Watchdog timer

4

Global alarm

5

Output 1

Loop 1 heat

Loop 1 heat

6

Output 2

Loop 2 heat

Loop 2 heat

7

Output 3

Loop 3 heat

Loop 3 heat

8

Output 4

Loop 4 heat

Loop 4 heat

9

Output 5

Pulse loop heat

Loop 5 heat

10

Output 6

Loop 1 cool

Loop 6 heat

11

Output 7

Loop 2 cool

Loop 7 heat

12

Output 8

Loop 3 cool

Loop 8 heat

13

Output 9

Loop 4 cool

Pulse loop heat

14

Output 10

Pulse loop cool

Loop 1 cool

15

Output 34

2

Serial DAC clock

Serial DAC clock

16

Input 1

17

Input 2

18

Input 3/Pulse input