Input Menu

Use the Input menu to configure the process input:

Input type

Engineering units

Scaling, calibration and filtering.

Input Type

Choose the type of sensor that is connected to the analog in-
put.

Values: See Table 5.7. For the pulse loop (CPC404 loop 5
or CPC408 loop 9), the only choices are pulse (7) and skip
(10).
Default: J T/C (1); for the pulse loop, pulse (7)
Modbus Address (Loops 1 to 9): 40103 to 40111
Parameter Number: 6
LogicPro Driver: Database
LogicPro Address (Loops 1 to 9): 6.1 to 6.9

Table 5.7

Input Types and Ranges

Display

Value

Modbus

or Logic

Value

Description

Input Range

J T/C

1

Type J thermocouple

-350 to 1400°F (-212 to 760°C)

K T/C

2

Type K thermocouple

-450 to 2500°F (-268 to 1371°C)

T T/C

3

Type T thermocouple

-450 to 750°F (-268 to 399°C)

S T/C

4

Type S thermocouple

0 to 3200°F (-18 to 1760°C)

R T/C

5

Type R thermocouple

0 to 3210°F (-18 to 1766°C)

B T/C

6

Type B thermocouple

150 to 3200°F (66 to 1760°C)

E T/C

20

Type E thermocouple

-328 to 1448°F (-200 to 787°C)

RTD

8

RTD

-328.0 to 1150.0°F (-200.0 to 621.1°C)

process

0

Voltage or current signal,
depending upon the hard-
ware configuration. See
Figure 1.2 on page 6.

User defined. See

Setting Up Process

Variable Retransmit on page 67.

pulse

7

Pulse input. Available only
for loop 5 on the CPC404
or loop 9 on the CPC408.

0 to 2000 Hz, scalable

skip

10

Loop is not used for con-
trol, does not report
alarms, and is not shown
on the scanning display.

(none)

l01 Input r
Other menus b

l01 Input type r
bJ T/C