beautypg.com

4 gp-3700 series, 4 gp-3700 series -24 – Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 233

background image

GP3000 Series Hardware Manual

9-24

9.4.4

GP-3700 Series

„Preparation

Please have the following ready beforehand.

Replacement backlight (Model: CA3-BLU15-01 (Set of two))

One pair of clean (preferably new) cotton gloves.

Phillips screwdriver (no.2)

About the Backlight

GP units use a CFL, long-life type backlight. In a real world situation, the backlight may need to be replaced

depending on the GP’s operating environment. It is recommended that it be replaced periodically.

A backlight life refer to “„Display Specifications (page 4-79)”, when the backlight is lit continuously (time

required for brightness to fall to half its normal level.)

„Procedure for replacing the backlight

There are two backlight of AGP-3750T.

Here is the procedure for replacing the backlight only for GP-3700 Series which is NOT marked

on GP Rev. 5.

[Electric shock]

• Whenever changing the backlight, be sure the GP’s power cord has been disconnected and that

the unit is cooled down.

• When the GP’s power cord is connected and the GP is ON, high voltage runs through the wires

in the backlight area do not touch them!

[Burn]

• When the GP’s power has just been turned OFF, the backlight area is still very hot! Be sure to

wear gloves to prevent being burned.

[Glass]

• The backlight is very fragile. Do not touch the glass tube directly or try to remove its power cord.

If the glass tube breaks you may be injured.