Structurel specifications – Proface AGP3500 - 10.4 DIO HMI" User Manual
Page 141
GP3000 Series Hardware Manual
4-76
Structurel Specifications
Inst
alla
ti
on
Grounding
Grounding resistance of 100
Ω 2mm
2
or thicker wire, or your country’s
applicable standard.
(Same for FG and SG terminals)
Structure
*1
*1
The front face of the GP unit, installed in a solid panel, has been tested using conditions
equivalent to the standards shown in the specification. Even though the GP unit’s level of
resistance is equivalent to these standards, oils that should have no effect on the GP can
possibly harm the unit. This can occur in areas where either vaporized oils are present, or
where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If
the GP’s front face protection sheet becomes peeled off, these conditions can lead to the
ingress of oil into the GP and separate protection measures are suggested.
Also, if non-approved oils are present, it may cause deformation or corrosion of the front
panel’s plastic cover. Therefore, prior to installing the GP be sure to confirm the type of
conditions that will be present in the GP’s operating environment.
If the installation gasket is used for a long period of time, or if the unit and its gasket are
removed from the panel, the original level of the protection cannot be guaranteed. To
maintain the original protection level, be sure to replace the installation gasket regularly.
Rating: Equivalent to IP65f NEMA #250 TYPE 4X/13
(Front surface at panel embedding)
Feature size: All-in-one
Installation configuration: Panel embedding
Cooling Method
Natural air circulation
Weight Approx.
5.6kg[12.3lb]max. (unit only)
External
Dimensions
W395mm[15.55in] X H294mm[11.57in] X D60mm[2.36in]
Panel Cut
Dimensions
W383.5mm[15.10in] X H282.5mm[11.12in]
*2
Panel Thickness: 1.6mm[0.06in] to 10.0mm[0.39in]
*3
*2
As for dimensional tolerance everything +1/-0mm[+0.04/-0in] and R in angle are below
R3[R0.12in].
*3
Even if panel thickness is within recommend range for “Panel Cut Dimensions”, the panel
could warp, depending on panel’s material, size, and installation location of GP or other
devices. To prevent panel warpage, the installation surface may need to be strengthened.
- AGP3400 - 7.5 DIO HMI" AGP3300 - 5.7 DIO HMI" AGP3600 - 12.1 FLEX Network HMIs" AGP3500 - 10.4 FLEX Network HMI" AGP3400 - 7.5 FLEX Network HMI" AGP3600 - 12.1 CANopen HMI" AGP3500 - 10.4 CANopen HMI" AGP3400 - 7.5 CANOpen HMI" AGP3300 - 5.7 CANopen HMI" AGP3300H - 5.7 Handheld HMIs" AGP3750 - 15 Multi-Media HMI" AGP3650 - 12.1 Multi-Media HMIs" AGP3550 - 10.4 Multi-Media HMIs" AGP3450 - 7.5 Multi-Media HMI" AGP3360 - 5.7 Multi-Media HMI" AST3300 - 5.7 Basic HMI" AST3200 - 3.8 Basic HMI" AGP3600 - 12.1 Standard HMIs" AGP3500 - 10.4 Standard HMIs" AGP3400 - 7.5 Standard HMI" AGP3300 - 5.7 Standard HMI" AGP3200 - 3.8 Standard HMI"