Proface LT3300 - 5.7 All-in-One HMI" User Manual
Introduction, Installation procedures, Installation guide
Step 1. Confirm the Display unit (1), moisture resistant gaske (2) and the
exclusive installation fasteners (5) are present.
Step 2. Make sure that the moisture resistant gasket is fitted properly to the
Display unit.
Step 3. Install the gasket (4) to the attachment (3) correctly.
Step 4. Attach the Display to the attachment prepared in Step 3 by using
the exclusive installation fasteners. Tighten the fastener attachment
screws. The proper torque for tightening a screw to obtain a
sufficient level of splash-proof is 0.5 N•m.
Step 5. Insert the attachment prepared in Step 4 into the cutout section of the
GP37W2 operation panel by matching the threaded portion of the
plate with the four corners of the panel.
Step 6. Confirm the gasket is installed correctly.
Step 7. Tighten the M4 hex nuts (6) evenly. The proper torque for tightening
a nut to obtain a sufficient level of splash-proof is 0.5 N•m.
Packing List
Attachment x1
Gasket x1
M4 Hex nut x6
Introduction
Do not over-tighten the hex nuts or the
attachment may be damaged.
screws or Display may be damaged.
Installation Procedures
Silver metallic
Item
Specified Value s
In
st
al
la
ti
o
n
R
e
q
u
ir
em
en
ts
Protective
Construction
Pr otection: Equivalent to IP65
(Fr ont face of installed unit )
Weight
0.25 kg or less
(Attachment only )
External Dimensions
(W)x(H)x(D) [mm]
207.0 x 157.0 x 17.0
Color
Material
Steel plate
Installation Guide
Panel Cutout Adapter(CA4-ATM5-01)
Head Office
Digital Electronics Corporation
8-2-52 Nanko-higashi
Suminoe-ku, Osaka 559-0031 JAPAN
Tel: +81-(0)6-6613-1101
Fax: +81-(0)6-6613-5888
URL: http://www.pr oface.co.j p/
C
Copyright 2004 Digital Electronics Corporation.All rights reserved.
We assume no
responsibility for any
losses, damages or any
claims from third party
resulting from the use of
this product.
Disclaimer
Exclusive
installation fastener x4
(two spa r es)
141.5mm
123.5mm
191.5mm
156mm
Finestra
Finestra
(3)
(4)
(6)
(1)
(5)
(2)
Magnified View
(2)
Completed Chart
Main unit and accessories
• Display unit x1 • • • • • • • • • • • • • • (1)
Option
• Moisture resistant gasket x1 • • • • • (2)
Option
•
Accessories of Display
• Attachment x1 • • • • • • • • • • • • • • (3)
• Gasket x1 • • • • • • • • • • • • • • • • • (4)
• Exclusive installation fastener x4 • • (5)
• M4 Hex nut x4 • • • • • • • • • • • • • • (6)
Before
After
GP-37W2 series
LT series
GP-3300 series
ST-3300 series
LT-3300 series
When the product is disposed of, it should be done so according to your country's
regulations for similar types of industrial waste.
Do not over-tighten the fastener attachment
This product is a conversion kit for replacing the current
display unit manufactured by Pro-face with a display unit
that has smaller panel cutout dimensions.
“Before”