Chapter 8 Installation and Wiring
8-7
8.2
Wiring Precautions
This section describes the procedures and precautions for wiring power cords.
8.2.1
Connecting the Power Cord
To avoid an electric shock, prior to connecting the GP unit’s power cord terminals to the
power terminal block, confirm that the GP unit’s power supply is completely turned OFF, via
a breaker, or similar unit.
Supplying a power voltage other than that specified will damage the power source and the
GP unit.
Since there is no power switch on the GP unit, be sure to attach a breaker-type switch to its
power cord.
When the FG terminal is connected, be sure the wire is grounded.
• When the FG terminal is connected, be sure the wire is grounded. Not grounding the
GP unit will result in excess noise and vibration.
• The SG and FG terminals are connected internally in the GP unit.
When connecting the SG wire to another device, be sure that the design of the
system/connection does not produce a shorting loop.
- AGP3400 - 7.5 DIO HMI" AGP3300 - 5.7 DIO HMI" AGP3600 - 12.1 FLEX Network HMIs" AGP3500 - 10.4 FLEX Network HMI" AGP3400 - 7.5 FLEX Network HMI" AGP3600 - 12.1 CANopen HMI" AGP3500 - 10.4 CANopen HMI" AGP3400 - 7.5 CANOpen HMI" AGP3300 - 5.7 CANopen HMI" AGP3300H - 5.7 Handheld HMIs" AGP3750 - 15 Multi-Media HMI" AGP3650 - 12.1 Multi-Media HMIs" AGP3550 - 10.4 Multi-Media HMIs" AGP3450 - 7.5 Multi-Media HMI" AGP3360 - 5.7 Multi-Media HMI" AST3300 - 5.7 Basic HMI" AST3200 - 3.8 Basic HMI" AGP3600 - 12.1 Standard HMIs" AGP3500 - 10.4 Standard HMIs" AGP3400 - 7.5 Standard HMI" AGP3300 - 5.7 Standard HMI" AGP3200 - 3.8 Standard HMI"