Chapter 9 Maintenance
9-23
(12) Return the rear face cover to the original position, and secure the cover in place using the mounting
screws (7). The necessary torque is 0.5N
•m.
• The cable clamp is used to prevent the cable from being caught inside in the GP unit
and possibly damaged. Be sure to insert the cable in the cable clamp around the
cable before replacing the rear cover.
• If any of the screws is missing, check if it fell inside the GP unit’s chassis. If the
power is turned ON while a screw is inside, it may cause an accident or fire.
•
After backlight replacement is completed, turn the GP unit’s power ON and check if the screen’s
display is normal. If the display is not correct, please contact the GP distributor from whom you
purchased the backlight unit.
- AGP3400 - 7.5 DIO HMI" AGP3300 - 5.7 DIO HMI" AGP3600 - 12.1 FLEX Network HMIs" AGP3500 - 10.4 FLEX Network HMI" AGP3400 - 7.5 FLEX Network HMI" AGP3600 - 12.1 CANopen HMI" AGP3500 - 10.4 CANopen HMI" AGP3400 - 7.5 CANOpen HMI" AGP3300 - 5.7 CANopen HMI" AGP3300H - 5.7 Handheld HMIs" AGP3750 - 15 Multi-Media HMI" AGP3650 - 12.1 Multi-Media HMIs" AGP3550 - 10.4 Multi-Media HMIs" AGP3450 - 7.5 Multi-Media HMI" AGP3360 - 5.7 Multi-Media HMI" AST3300 - 5.7 Basic HMI" AST3200 - 3.8 Basic HMI" AGP3600 - 12.1 Standard HMIs" AGP3500 - 10.4 Standard HMIs" AGP3400 - 7.5 Standard HMI" AGP3300 - 5.7 Standard HMI" AGP3200 - 3.8 Standard HMI"