IAI America SCON-C User Manual
Page 69
51
3.10.4 24 V Power Supply Connector
Connector on
cable side
MC1.5 / 2-STF-3.5 (Phoenix Contact)
Conforming cable
AWG28 to 16
1
0 V
Power supply ground for brake excitation
Terminal assignment
2
24 VIN
+24 V power supply for brake excitation
* It is necessary to supply +24 V to the brake power supply connector of the controller as well.
3.10.5 Brake Release External Switch Connectors 1 and 2
Connection
destination device
Break release switch
Connector on
cable side
XAP-02V-1
(Contact BXA-001T-P0.6) (JST)
Switch rating
30 VDC, minimum current 1.5 mA
1
BKMRL
Brake release switch input
Terminal assignment
2
COM
Brake release switch input power supply output
* If the connector pins 1 and 2 are short circuited, the brake is forcefully released.
3.10.6 Connection
Input +24 V power supply to the 24 V power supply connector of the external brake connection box.
Controller connection diagram
SCON 400 W or higher
Motor cable
Encoder cable
Actuator
External brake connection box
Encoder cable