IAI America SCON-C User Manual
Page 186
168
(9) Feedback pulse pattern
No.
Name
Symbol
Unit
Input range
Default setting
69
Feedback pulse pattern
FBPT
-
0 to 2
0
You can set a desired pattern in which to output feedback pulses.
If the actuator encoder is not a serial encoder, the
phase-Z signal is output directly.
If the actuator uses a serial encoder, the phase-Z pulse
is output within a mechanical-angle range of
0.5 from
the zero (home) position. Based on the communication
cycle with the encoder, this precision can be assured
when the motor speed is 100 rpm or below.
* The actuator is using a serial encoder if the number
of encoder pulses is 16,384 (pulses/rev).
(10) Feedback-pulse
pattern
polarity
No.
Name
Symbol
Unit
Input range
Default setting
70
Feedback-pulse pattern polarity
FBPT
-
0 to 1
0
You can set a desired polarity to be applied to the feedback pulse pattern.
Setting 0: Positive logic
Setting 1: Negative logic
ZFB
/ZFB
Command pulse-train
pattern
Input terminal
Forward
Reverse
Neg
a
ti
ve lo
gic
P
osit
ive lo
gic
Forward pulse train
Reverse pulse train
A forward pulse train indicates motor revolutions in the forward direction, while a reverse pulse train indicates motor
revolutions in the negative direction.
Pulse train
Sign
Command pulses indicate motor revolutions, while a command sign indicates a rotating direction.
Phase-A/B pulse
train
Phase-A/B x4 pulses with a 90
phase difference indicate motor revolutions and a rotating direction.
Forward pulse train
Reverse pulse train
Pulse train
Sign
Phase-A/B pulse
train
Setting
2
1
0
2
1
0
AFB
/AFB
BFB
/BFB
AFB
/AFB
BFB
/BFB
AFB
/AFB
BFB
/BFB
AFB
/AFB
BFB
/BFB
AFB
/AFB
BFB
/BFB
AFB
/AFB
BFB
/BFB
Low
Low
High
High