Alarm level classification, 2 alarm level classification – IAI America SCON-C User Manual
Page 226
208
Appendix
5.2 Alarm Level Classification
Alarms are classified into two levels based on the corresponding symptoms.
Alarm level
ALM lamp
*ALM signal
What happens when alarm
generates
How to reset
Operation
cancellation
Lit
Output
The actuator decelerates to
a stop and then the servo
turns OFF.
Alarm reset using an I/O, PC or
teaching pendant
Cold start
Lit
Output
The actuator decelerates to
a stop and then the servo
turns OFF.
Software reset using a PC or
teaching pendant or reconnection
of power
Caution:
Reset each alarm after identifying and removing the cause of the alarm. If the cause of the alarm
cannot be removed or the alarm still persists after the cause has been removed, contact IAI.
If the same error occurs again after resetting the alarm, it means that the cause of the alarm still
remains.
- ERC2 (188 pages)
- ERC2 (138 pages)
- ERC3 (438 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- NS (78 pages)
- ICS(P)A (16 pages)
- RS (46 pages)