IAI America SCON-C User Manual
Page 214
196
Appendix
Speed loop integral gain
Parameter No.
Unit
Input range
Default
32
---
1 to 217270
Set individually in accordance with the
actuator characteristics.
Torque filter time constant
Parameter No.
Unit
Input range
Default
33
---
1 to 2500
Set individually in accordance with the
actuator characteristics.
This parameter determines the filter time constant for torque commands.
If the resonance frequency of the machine is smaller than the response frequency of the servo loop, the motor
vibrates.
This mechanical resonance can be suppressed by increasing the value set in this parameter.
However, increasing the parameter value excessively may reduce the stability of control.
Current-control band number
Parameter No.
Unit
Input range
Default
54
---
0 to 7
Set individually in accordance with the
actuator characteristics.
This parameter sets the control band for PI current control.
Normally this parameter need not be changed, so the customer is advised not to change the setting.
If the parameter is changed carelessly, control safety may be adversely affected and a very dangerous situation
may result.
However, changing this parameter may be effective in certain situations, such as when the actuator generates
resonance noise that can be suppressed by changing this parameter.
Even in this case, the customer is advised to consult IAI and change the parameter according to the instruction
given.
This parameter determines the level of response with respect to a speed control loop.
Decreasing the setting results in lower response to the speed command and decreases the reactive
force upon load change. If the setting is too low, compliance with the position command drops and the
positioning time increases as a result.
Increasing the setting too much increases the tendency of the actuator to overshoot or oscillate,
resulting in increased mechanical vibration.
Speed
Setting is low
Setting is high (overshoot)
Time