IAI America SCON-C User Manual
Page 146

128
Push & hold operation using the incremental position number
Example) If a position 2 command is input followed by a start signal while the actuator is moving to position 1, a
new target position will be set by adding the incremental distance to the current position where the
start input was received. Since the target position is indeterminable, never use this method.
Position table (Field(s) within thick line must be entered.)
0
1
2
200.00
15.00
=
100.00
20.00
30.00
60.00
50
50
0
1
Position
[mm]
Speed
[mm/ss]
Positioning
band
[mm]
Push
[%]
Incremental
* On the RCM-T teaching pendant, this symbol indicates that the
applicable position is specified in relative coordinates.
Incremental
feed
Command position
Start
Position complete
Actuator movement
15 mm
Distance
Speed
Position 1
Position 2
Initial target position:
200 mm
Position where the start input
was received
Position where the
push & hold
operation completed
No.
- ERC2 (138 pages)
- ERC2 (188 pages)
- ERC3 (438 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- NS (78 pages)
- ICS(P)A (16 pages)
- RS (46 pages)