Page 95

background image

5. Data Entry

72

(9) Acceleration/deceleration

mode

x

This field is not used for this controller.

The factory setting is “0.”

(10) Incremental

x

This setting defines whether to use the absolute mode or incremental mode.

The factory setting is “0.”

0: Absolute mode

1: Incremental mode

(11) Command mode

x

This field is not used for this controller.

The factory setting is “0.”

(12) Standstill mode

x

This setting defines the power-saving mode to be applied when the actuator is

standing by after completing the positioning to the target position set in the

“Position” field for the applicable position number.

0: All power-saving modes are disabled. * The factory setting is “0: [Disable].”

1: Automatic servo-off mode. The delay time is defined by parameter No. 36.

2: Automatic servo-off mode. The delay time is defined by parameter No. 37.

3: Automatic servo-off mode. The delay time is defined by parameter No. 38.

4: Full servo control mode

Full servo control mode

The pulse motor is servo-controlled to reduce the holding current.

Although the exact degree of current reduction varies depending on the actuator model, load condition, etc., the

holding current decreases to approx. one-half to one-fourth.

Since the servo remains on, no position deviation occurs.

The actual holding current can be checked in the current monitor screen of the PC software.

Automatic servo-off mode

After positioning is completed, the servo will turn off upon elapse of a specified time.

(Since no holding current flows, the power consumption decreases.)

When the PLC issues the next movement command, the servo will turn on and the actuator will start moving.

Movement

command

Servo status

Actuator

movement

Servo on

Automatic servo-off mode

(the green LED blinks)

Target position

T: Delay time after the positioning is

completed until the servo turns off (sec).

Set by a parameter.