8. Parameter Settings

124

8.2.2 Parameters Relating to the Actuator Operating Characteristics

z

Default speed

The factory setting is the rated speed of the actuator.

When a target position is set in an unregistered position table, the setting in this parameter will be used as the speed

data for the applicable position number.

To reduce the default speed from the rated speed, change the setting in parameter No. 8.

z

Default acceleration/deceleration

The factory setting is the rated acceleration/deceleration of the actuator.

When a target position is set in an unregistered position table, the setting in this parameter will be used as the

acceleration/deceleration data for the applicable position number.

To reduce the default acceleration/deceleration from the rated acceleration/deceleration, change the setting in

parameter No. 9.

z

Default positioning band (in-position)

The factory setting is “0.10 [mm].”

When a target position is set in an unregistered position table, the setting in this parameter will be used as the

positioning band data for the applicable position number.

Increasing the default positioning band will allow the position complete signal to be output early. Change the setting in

parameter No. 10, as necessary.

z

Current-limiting value during home return

The factory setting conforms to the standard specification of the actuator.

Increasing this setting will increase the home return torque.

This setting need not be changed in normal conditions of use. However, if an increased slide resistance causes the

home return to complete before the correct position depending on the affixing method, load condition or other factor

when the actuator is used in a vertical application, the value set in parameter No. 13 must be increased.

(Do not increase the value beyond 75%.)

z

Current-limiting value at standstill during positioning

The factory setting conforms to the standard specification of the actuator.

Increasing this setting will increase the holding torque at standstill.

This setting need not be changed in normal conditions of use. However, to prevent hunting caused by large external

force applied while the actuator is at standstill, the value set in parameter No. 12 must be increased.

(Do not increase the value beyond 70%.)

z

Speed override

Use this parameter when moving the actuator at a slower speed to prevent danger when the system is initially started

for test operation.

When movement commands are issued from the PLC, the moving speed set in the “Speed” field of the position table

can be overridden by the value set in parameter No. 46.

Actual moving speed = [Speed set in the position table] x [Value of parameter No. 46] y 100

Example) Value in the “Speed” field of the position table

500 (mm/s)

Value of parameter No. 46

20 (%)

Under the above settings, the actual moving speed becomes 100 mm/s.

The minimum setting unit is “1 [%],” while the input range is “1 to 100 [%].” The factory setting is “100 [%].”

(Note) This parameter is ignored for movement commands from the PC and teaching pendant.