0

5. Data Entry

71

“Push & hold operation”

The set value defines the maximum distance the actuator will push the work

part in the push & hold mode upon reaching the target position.

Consider the mechanical variations of the work part and set an appropriate

positioning band so that positioning will not complete before the actuator

contacts the work part.

(8) Zone+/–

x

These settings define the zone in which the zone output signal will turn ON

when PIO pattern 3 is selected.

For added flexibility, different values can be set for each target position.

[Setting example]

The position complete signal turns ON here, because the

actuator has contacted the load and the controller has

determined that the push & hold operation has completed.

Work part

Positioning band

(Maximum push distance)

Target position

Position

Zone+

Zone–

Movement command to position No. 0

Zone output signal

Home