IAI America ERC2 User Manual
Page 94

0
5. Data Entry
71
“Push & hold operation”
The set value defines the maximum distance the actuator will push the work
part in the push & hold mode upon reaching the target position.
Consider the mechanical variations of the work part and set an appropriate
positioning band so that positioning will not complete before the actuator
contacts the work part.
(8) Zone+/–
x
These settings define the zone in which the zone output signal will turn ON
when PIO pattern 3 is selected.
For added flexibility, different values can be set for each target position.
[Setting example]
The position complete signal turns ON here, because the
actuator has contacted the load and the controller has
determined that the push & hold operation has completed.
Work part
Positioning band
(Maximum push distance)
Target position
Position
Zone+
Zone–
Movement command to position No. 0
Zone output signal
Home