beautypg.com

7 i/o signals for pio pattern 0 [8 points, 1 explanation of i/o signals – IAI America ERC2 User Manual

Page 67

background image

3. W
iring

44

3.7 I/O Signals for PIO Pattern 0 [8 Points]

Caution The factory setting is “8 points.”

The pause signal can be disabled in parameter No. 15.

(Note) *STP and *ALM are always ON.

3.7.1 Explanation of I/O Signals

Category

Signal name

Signal

abbreviation

Function overview

Start

CSTR

Movement of the actuator starts at the rise edge of this signal.

Command position

number

PC1

PC2

PC4

This signal is used to input a position number that specifies movement.

Be sure to set a command position number by 6 ms before the start signal

(CSTR) is turned ON.

*Pause

*STP

ON: The actuator can be moved, OFF: The actuator decelerates to a stop

Input

Home return

HOME

Home return starts at the rise edge of this signal.

Position complete

PEND

This signal turns ON when the actuator has moved close enough to the

target position and entered the in-position band.

Used to determine if positioning has completed.

Home return

completion

HEND

This signal turns OFF when the power is input, and turns ON when home

return completes.

Zone

ZONE

This signal is output if the current actuator position is within the range set

by the parameter upon completion of home return.

Used as a limit switch for an intermediate point or a simple ruler for push &

hold operation.

Output

*Alarm

*ALM

This signal remains ON while the controller is operating properly, and turns

OFF when an alarm generates.

(Note) The signal remains ON while the motor drive power is cut off.

Orange (Red 2)

Orange (Black 2)

*Light blue (Red 2)

*Light blue (Black 2)

White (Red 2)

White (Black 2)

Yellow (Red 2)

Yellow (Black 2)

Pink (Red 2)

Pink (Black 2)

6A

PC1

6B

PC2

7A

PC4

7B

HOME

8A

CSTR

8B

*STP

9A

PEND

9B

HEND

10A

ZONE

10B

*ALM

Host system

ERC2 actuator end

CN1

(Signal abbreviation)

Output

side

Input

side

Command position 1

Command position 2

Command position 4

Home return

Start

Pause

Position complete

Home return completion

Zone output

Alarm

* Robot cable

Gray (Red 2)

Gray (Black 2)