4 parameter records – IAI America ERC2 User Manual
Page 185

11.
Appendix
Appendix
11.4 Parameter Records
Recorded date:
Category:
a: Parameter relating to the actuator stroke range
b: Parameter relating to the actuator operating characteristics
c: Parameter relating to the external interface
d: Servo gain adjustment
No.
Category
Name
Unit
Recorded data
1
a
Zone boundary 1+
mm
2
a
Zone boundary 1–
mm
3
a
Soft limit+
mm
4
a
Soft limit–
mm
5
a
Home return direction
(0: [Reverse]/1: [Forward])
-
6
b
Push & hold stop judgment period
msec
7
d
Servo gain number
-
8
b
Default speed
mm/sec
9
b
Default acceleration/deceleration
G
10
b
Default positioning band (in-position)
mm
12
b
Current-limiting value at standstill during
positioning
%
13
b
Current-limiting value during home return
%
15
c
Pause input disable selection
(0: [Enable]/1: [Disable])
-
16
c
SIO communication speed
bps
17
c
Minimum delay time for slave transmitter
activation
msec
22
a
Home return offset
mm
25
c
PIO pattern selection
-
27
c
Movement command type (0: [Level]/1: [Edge])
-
28
b
Default direction of excited-phase signal
detection (0: [Reverse]/1: [Forward])
-
29
b
Excited-phase signal detection time
msec
31
d
Speed loop proportional gain
-
32
d
Speed loop integral gain
-
33
d
Torque filter time constant
-
34
b
Push speed
c
e
s
/
m
m
35
b
Safety speed
c
e
s
/
m
m
36
b
Automatic servo-off delay time 1
sec
37
b
Automatic servo-off delay time 2
sec
38
b
Automatic servo-off delay time 3
sec
39
c
Output mode of position complete signal (0:
[PEND]/1: [INP])
-
40
c
Home-return input disable selection (0:
[Enable]/1: [Disable])
-
45
c
Silent interval multiplication factor
times
46
b
Speed override
%
53
b
Default standstill mode
-