109

7.8 Operation at Different Acceleration and Deceleration Settings

In applications where the work part or peripheral equipment should not receive impact or vibration when the actuator

is standing still, you can apply a gradual curve only during deceleration.

Example of use in operation) Move the actuator from the home to the 150-mm position (position 1) at a speed of

200 mm/sec. The acceleration and deceleration are to be 0.3 G and 0.05 G,

respectively.

Method) Set “0.3” G in the “Acceleration” field and “0.05” G in the “Deceleration” field of the

position table.

ERC2 controller

P

L

C

[4] [2]

[1]

[5] [3]

Signal name

Start

Command position 1

Command position 2

Command position 4

Command position 8

*Pause

Position complete

Home return completion

Zone

*Alarm

Category

Input

Output

PIO

Reference flow

Select/enter command position 1.

Start input ON

Position complete output OFF

Start input OFF

Movement to position 1 completes.

Position complete output turns

ON 0.1 mm before position 1.

Movement to position 1 starts at 0.3 G.

Moves at constant speed (200 mm/sec).

Deceleration starts at 0.05 G.

[1]

[2]

[3]

[4]

[5]