beautypg.com

Extron Electronics MTPX Plus 6400 Series User Guide User Manual

Page 80

background image

Command/Response Table for SIS Commands (continued)

Command

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional Description

Input skew adjustment

Set all input skew
adjustment values

EX#

*

X(

*

X(

*

X(

Iseq

}

Iseq

X#

*

X(

*

X(

*

X(]

Set a specific skew adjustment for the TP
input.

X(

values are listed in RGB order.

Example:

E

2*Ш*Ш*4Iseq

}

IseqØ2*ШШ*ШШ*Ш4

]

Set input 2 skew settings as follows:
Red = 0 ns

Green = 0 ns

Blue = 8 ns.

Increment one input skew
adjustment value

EX#

*

X1)

+Iseq

}

Iseq

X#

*

X(

*

X(

*

X(]

Increase the

X1)

plane skew adjustment for

input

X#

by 1 step (2 ns).

Example:

E

2*2+Iseq

}

IseqØ2*ШШ*ШШ*Ш5

]

Increase the blue skew for input 2 by 2 ns to
10 ns.

Decrement one input skew
adjustment value

EX#

*

X1)

-Iseq

}

Iseq

X#

*

X(

*

X(

*

X(]

Decrease the

X1)

plane skew adjustment for

input

X#

by 1 step (2 ns).

Read input skew
adjustment values

EX#

Iseq

}

X(

*

X(

*

X(]

EDID commands

Assign EDID data to an
input

E

A

X1!

*

X1@

EDID

}

EdidA

X1!

*

X1@]

Assign EDID data to all
inputs

E

A*

X1@

*EDID

}

EdidAØ*

X1@]

Save output 1 EDID data to
a user-defined space

E

S*

X1@

EDID

}

EdidS

X1@]

For this command, the

X1@

value must be from

31 to 34.

View EDID data assigment

E

A*

X1!

EDID

}

X1@]

Show the EDID setting for input

X1!

.

Output pre-peaking

Set output pre-peaking on

EX@

*1Opek

}

Opek

X@

*1

]

Pre-peak the TP output.

Set output pre-peaking off

EX@

*ØOpek

}

Opek

X@

]

Do not pre-peak the TP output.

Read output pre-peaking
setting

EX@

Opek

}

X1#]

Local video output sync polarity

Set local output polarity

EX1$

*

X1%

Opol

}

Opol

X1$

*

X1%]

Set the horizontal and vertical sync polarity for
local output

X1$

.

Example:

E

2*ØOpol

}

Opol2*Ø

]

Set local output 2 to output negative
horizontal and vertical sync.

Read local output sync
settings

EX1$

Opol

}

X1%]

Output skew adjustment

Set all output skew
adjustment values

EX1^

*

X(

*

X(

*

X(

Oseq

}

Oseq

X1^

*

X(

*

X(

*

X(]

Set a specific skew adjustment for the TP
output.

X(

values are listed in RGB order.

Example:

E

2*Ш*Ш*4Oseq

}

OseqØ2*Ш*Ш*4

]

Set the output 2 skew settings as follows:
Red = 0 ns

Green = 0 ns

Blue = 8 ns.

Increment one output skew
adjustment value

EX1^

*

X1)

+Oseq

}

Oseq

X1^

*

X(

*

X(

*

X(]

Increase the

X1)

plane skew adjustment

output

X1^

by 1 step (2 ns).

Decrement one output
skew adjustment value

EX1^

*

X1)

-Oseq

}

Oseq

X1^

*

X(

*

X(

*

X(]

Decrease the

X1)

plane skew adjustment

output

X1^

by 1 step (2 ns).

Example:

E

2*2-Oseq

}

OseqØ2*Ш*Ш*3

]

Decrease the output 2 blue skew by 2 ns to 6 ns.

Read output skew
adjustment values

EX1^

Oseq

}

X(

*

X(

*

X(]

NOTE:

X@

= Output number

01 – (maximum number of outputs for your matrix size)

X#

= TP input number

01 – (maximum number of TP inputs for your matrix size)

X(

= Skew adjustment range

00 – 31 (each step = 2 ns)

X1)

= Video plane

0 = red

1 = green

2 = blue

X1!

= Input number

01 – (maximum number of inputs for your matrix size)

X1#

= Pre-peaking status

0 = off

1 = on

X1@

= DDC value (EDID)

See the complete definition on

page 71

.

X1$

= Local video output number

01 – 04

X1%

= Local output sync polarity

0 = H– / V– (default)

2 = H – / V+

4 = No sync stripping

1 = H+ / V–

3 = H+ / V+

X1^

= TP output number

01 – (maximum number of TP outputs for your model)

MTPX Plus 6400 Series Matrix Switchers • Programming Guide