Extron Electronics MTP SW6 Setup Guide User Manual
Mtp sw6 • setup guide, Installation, Step 1 — mounting
IMPO
RTAN
T:
Go to www
.extron.com f
or the complete
user guide
, installation instructions,
and
specifications bef
ore connecting the
product to the po
wer sour
ce.
MTP SW6 • Setup Guide
This card provides quick start instructions for an experienced installer to set up and operate the MTP SW6 switcher.
Installation
Step 1 — Mounting
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Wire color
T568A
T568B
White-orange
Orange
White-green
White-blue
Green
White-brown
Brown
Blue
Blue
Insert
TP Wires
Pins:
12345678
1
2
3
4
5
6
INPUT
PRE-PEAK
ON
OFF
OUTPUT
NOTE
:
If you are using Enhanced Skew-Free™ A/V cable,
use the TIA/EIA T568A standard only.
Turn off or disconnect all equipment power sources and mount the MTP switcher as required.
Step 2 — TP Inputs from the Transmitters
Terminate up to six TP cables as shown at right. Connect them between MTP transmitters
and the Input connectors (both ends need to match).
Step 3 — RS-232 Insert Connector
For bidirectional RS-232 data that is routed from a common source to the TP output
regardless of the selected input, plug a serial device into the RS-232 Insert connector.
NOTES:
•
For the RS-232 insert to be available on the TP output, it must be enabled by issuing
the
E
1*1Lrpt
}
SIS command to the switcher (see the MTP SW6 User Manual).
•
When the RS-232 insert is enabled, any content on the audio/RS-232 wire pair for the
TP input tied to the output is disabled.
Step 4 — TP Output to the Receiver
Terminate a TP cable as shown for step 2. Connect it between the Output connector and receiver
that is compatible with the transmitters.
NOTE: The input and all outputs should all be terminated using the same standard on both
ends of the cables.
Step 5 — Connect a Local Audio Device
Connect an audio device to the Mono Audio connector. Wire the connectors as shown at right.
ATTENTION: For unbalanced audio output, connect the sleeves to the ground contact. DO
NOT connect the sleeves to the negative (-) contacts.
Step 6 — Remote Connector (Optional)
Connect an RS-232 device OR a contact closure device, such as a KP 6 Keypad Remote Control.
NOTES:
•
For RS-232 control, use a cable with ONLY pins 2, 3, and 5 connected.
•
For contact closure control, use a cable with pins 2 and 3 NOT connected.
RS-232 communications protocols:
•
9600 baud
•
8 data bits
•
1 stop bit, no parity
•
no flow control
For contact closure control, short the pin for the desired input to pin 5 to select that device. To
force an input to be always selected, leave the short in place.
NOTES:
•
For contact closure control, auto switch mode must be off.
•
Contact closure control overrides front panel input selections.
Receive (Rx)
Transmit (Tx)
Ground ( )
Bidirectional
RS-232 Device
Ground ( )
Receive (Rx)
Transmit (Tx)
Rx
Tx
SP
ARE
Do not tin the wires!
REMOTE
1
MONO AUDIO
2
1
MONO AUDIO
2
Unbalanced Output
Balanced Output
Do not tin the wires!
Mono output 1-
Sleeve(s)
Mono output 1+
Mono output 2+
Mono output 2-
Sleeve(s)
Mono output 1
Mono output 2
NO GROUND.
NO GROUND.
Pin
RS-232
Contact
Closure
Function
1
—
In #1
Input #1
2
TX
—
Transmit data
3
RX
—
Receive data
4
—
In #2
Input #2
5
Gnd
Gnd
Ground
6
—
In #3
Input #3
7
—
In #4
Input #4
8
—
In #5
Input #5
9
—
In #6
Input #6