If out 2, Powering up/down, Before powering up – TANDBERG E5714 User Manual
Page 49: Powering up, Powering down, 7 powering up/down, 1 before powering up, 2 powering up, 3 powering down
Installing the Equipment
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
Page 2-21
ST.TM.E10076.3
IF Out 2
A 75 W BNC socket provides a 70 MHz IF output used for
monitoring.
Table 2.18: IF Out 2 Connector
Item
Specification
Connector Type
BNC 75
W Female
Type
Analogue
Connector designation
IF Out 2
Pin-outs
Centre
Signal
Screen
Ground
2.7
Powering Up/Down
2.7.1
Before Powering Up
Before powering up the Encoder, check that:
1. The unit has been installed in a suitable location.
2. The unit has been connected to external equipment and power supply,
as required.
3. The power supply has been checked and a good earth provided.
4. The correct fuse type and rating has been fitted to the equipment and,
for the ac supply version, the ac power cable.
2.7.2
Powering Up
To power up the Encoder:
1. Turn on the local power supply. The Encoder executes a series of
power-up initialisation and self-test routines.
2. Confirm that the green Power LED is lit and that the red Alarm LED is
unlit.
3. Ensure that the Stand-by switch is set to On (see Chapter 1,
Introduction, Figure 1.8).
After the boot period the Encoder Input Monitor screen is displayed.
NOTES…
1.
The fans on the Encoder can be temperature controlled so may not be on if the ambient
temperature is low. Refer to Annex B, Technical Specification for more information.
2.
During initialisation invalid PIDs may appear momentarily in the transport stream.
2.7.3
Powering Down
To power down the Encoder remove the power supply connection at the
rear of the unit.