Control and monitoring, Remote control - ethernet 1 and 2, Local control – TANDBERG E5714 User Manual
Page 249: Alarm, Remote control, Rs-232 data (asynchronous), B.4 control and monitoring, B.4.1 remote control - ethernet 1 and 2, B.4.2 local control, B.4.3 alarm
Technical Specification
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
Page B-13
ST.TM.E10076.3
B.4
Control and Monitoring
B.4.1
Remote Control - Ethernet 1 and 2
Table B.21: Ethernet Specification
Item
Specification
Safety status
SELV
Connector designation
ETHERNET#1 and ETHERNET#2
Connector type
8-way RJ-45 socket, 10BaseT (ISO 882/3)
B.4.2
Local Control
Local control is by means of the front panel keypad and LCD display.
B.4.3
Alarm
Table B.22: Alarm Specification
Item
Specification
Safety status
SELV
Connector designation
ALARM
Connector type
9-way D-type male
Alarm contacts
Change-over contacts (5
W in common)
Fail contacts
Change-over contacts (5
W in common)
Reset contacts
Short pins 9 and 5 (resets the Encoder)
Relay Contact Rating
Maximum switching power
30 W
Maximum switching voltage
110 V
Maximum switching current
1 A
B.4.4
Remote Control
This connector provides an RS-232/RS-485 user interface control port that
allows the unit to be controlled by an external master.
Table B.23: Remote Control Specification
Item
Specification
Safety status
SELV
Connector designation
REMOTE CONTROL
Connector type
9-way D-type male
B.4.5
RS-232 Data (Asynchronous)
RS-232 is not currently supported on the Base Board in Build version 2.0.0
but it is in the option module M2/EOM2/DAT.