beautypg.com

Connecting the encoder to the ac power supply, Dc operating voltage and earthing, Dc power supply – TANDBERG E5714 User Manual

Page 36: 5 dc operating voltage and earthing, 1 dc power supply

background image

Installing the Equipment

Page 2-8

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

ST.TM.E10076.3

The unit has a Technical earth terminal (marked with ) located at the

rear panel. Its use is recommended. This is NOT a Protective earth for

electric shock protection. The terminal is provided to:
1. Ensure all equipment chassis fixed within a rack are at the same

Technical earth potential. To do this, connect a wire between the

Technical earth terminal and a suitable point on the rack.

2. Eliminate the migration of stray charges when connecting between

equipment.

WARNING...

IF THE TERMINAL SCREW HAS TO BE REPLACED, USE THE FOLLOWING:

1U ENCODER - M4 X 10 mm LONG POZIDRIV PANHEAD.

2U ENCODER - M5 X 12mm LONG POZIDRIV PANHEAD.

USING A LONGER SCREW MAY CAUSE A SAFETY HAZARD.

Connecting the Encoder to the AC Power Supply

WARNINGS...

1. DO NOT OVERLOAD WALL OUTLETS AND EXTENSION CORDS AS THIS CAN RESULT IN A

RISK OF FIRE OR ELECTRIC SHOCK.

2. AS NO MAINS SWITCH IS FITTED TO THIS UNIT, ENSURE THE LOCAL AC POWER SUPPLY IS

SWITCHED OFF BEFORE CONNECTING THE SUPPLY CORD.

3. THE ENCODER IS NOT FITTED WITH AN ON/OFF SWITCH. ENSURE THAT THE SOCKET-

OUTLET IS INSTALLED NEAR THE EQUIPMENT SO THAT IT IS EASILY ACCESSIBLE.

FAILURE TO ISOLATE THE EQUIPMENT PROPERLY MAY CAUSE A SAFETY HAZARD.

To connect the unit to the local ac power supply:
1. Ensure the local ac supply is switched OFF.
2. Ensure the correct fuse type and rating has been fitted to both the

equipment and the ac power cable.

3. Connect the ac power lead to the Encoder mains input connector and

then to the local mains supply.

2.5

DC Operating Voltage and Earthing

2.5.1

DC Power Supply

WARNING...

THE ENCODER IS NOT FITTED WITH AN ON/OFF SWITCH. PROVIDE AN ACCESSIBLE,

EXTERNAL MEANS OF DISCONNECTION. FAILURE TO ISOLATE THE EQUIPMENT PROPERLY

MAY CAUSE A SAFETY HAZARD.

CAUTIONS...

1. This product should be operated only from the type of power source indicated on the marking label.

If you are not sure of the type of power supply where the Encoder is to be mounted, consult a

qualified electrical engineer for the vehicle, the vehicle manufacturer or their agents.

2. The Encoder can be connected to a positive or negative earth system but you must ensure that

correct polarity to the DC input connections are maintained.