Remux related errors, H.11 remux related errors – TANDBERG E5714 User Manual
Page 311
Error Messages
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
Page H-9
ST.TM.E10076.3
H.11 Remux Related Errors
Table H.9: Remux Error Messages
Error Message
Action to Take
Overflow On Input 1
Overflow On Input 2
Overflow On Input 3
Reduce incoming bit-rate.
Overflow Motherboard O/P
Reduce incoming bit-rate of services, or turn off some services.
Remux Card Stopped
Power Encoder off, then check that the Remux module is firmly seated in the
chassis. Do this by firmly pressing it from the rear of the Encoder into the chassis.
Power on the Encoder. If the fault persists call Service Engineer.
Motherboard O/P TS
Power Encoder off, then check that the Base Board is firmly seated in the
chassis. Do this by firmly pressing it from the rear of the Encoder into the chassis.
Power on the Encoder. If the fault persists call Service Engineer.