Operating the Equipment Locally

Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder

Page 4-107

ST.TM.E10076.3

4.14.4 IRD Demod Menu

Frequency Option

To access the Frequency option, press the Frequency softkey in the IRD
Demod Menu

.

This value is either the L-Band frequency for the demodulator to tune to if

the LNB option is set to ‘Direct RF’, or it is the satellite frequency to tune

to if the LNB option is set to ‘Active’.
If the demodulator is M2/EOM2/QPSKDEMOD, and the IF input is selected,

then this value is the IF frequency to tune to.

Symbol Rate Option

To access the Symbol Rate option, press the Symbol Rate softkey in the

IRD Demod Menu

. If the IRD is in tracking mode then this value is tied to

that set for the satellite modulator, and cannot be altered.

Table 4.134: Symbol Rate Options

Valid Input Range

Description

Min (Low Sym Rate)

0.3000 Msym/s

Minimum with low symbol rate option M2/ES02/LSYM

Min

1.0000 Msym/s

Max

30.0000 Msym/s

Stepsize

0.0001 Msym/s

FEC Rate Option

To access the FEC Rate option, press the FEC Rate softkey in the

IRD

Demod Menu

. If the IRD is in tracking mode this value is tied to that set for

the satellite modulator, and cannot be altered.

Table 4.135: FEC Rate Options

Selected Option

Description

1/2

IRD uses 1/2 FEC Rate

2/3

IRD uses 2/3 FEC Rate

3/4

IRD uses 3/4 FEC Rate

5/6

IRD uses 5/6 FEC Rate

7/8

IRD uses 7/8 FEC Rate

8/9

IRD uses 8/9 FEC Rate - only applicable if the modulation type is 8PSK