Remote control, Data, Rs-232 connector – TANDBERG E5714 User Manual
Page 45: 9 data
Installing the Equipment
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
Page 2-17
ST.TM.E10076.3
Remote Control
A 9-way, D-type male connector provides an
RS-232/RS-485 port for remote control of the
Encoder (see Serial Protocol Option). This
connector is wired as a DTE.
Table 2.10: Remote Control Connector (RS-232/ RS-485)
Remote (DTE)
Encoder (DTE) Remote Control
Signal Name
Signal Direction
Pin
Signal Name
1
Not connected
Transmit Data
2
Received Data (RS-232)
Received Data
3
Transmit Data (RS-232)
4
Not connected
Signal Ground
5
Signal Ground
Transmit Data B
6
Received Data B (RS-485)
Received Data A
7
Transmit Data A (RS-485)
Received Data B
8
Transmit Data B (RS-485)
Transmit Data A
9
Received Data A (RS-485)
NOTES…
1.
Signal names are with respect to a DTE in accordance with the RS-232 and RS-485
specification. A is positive and B is negative.
2.
A null modem connection must be used when connecting DTE together.
2.6.9
Data
RS-232 Connector
RS-232 data is available on the Base Board
2
and the option module
M2/EOM2/DAT.
Table 2.11: RS-232 Data Connector (Base Board) - Asynchronous
Remote (DTE) Male
Encoder RS-232 (DTE) Female
Signal Name
Pin
Signal Direction
Pin
Signal Name
1
1
Not connected
Received Data
2
2
Received Data
Transmit Data
3
3
Transmit Data
4
4
Not connected
Signal Ground
5
5
Signal Ground
6
6
Not connected
7
7
Not connected
8
8
Not connected
9
9
Not connected
2