L-band out (main), L-band out (monitor), Up-converter power – TANDBERG E5714 User Manual
Page 48: Ofdm modulator outputs (e5715 and e5750), If out 1
Installing the Equipment
Page 2-20
Instruction Manual: evolution 5000 E57xx DSNG and DENG Voyager Encoder
ST.TM.E10076.3
L-Band Out (Main)
50 W SMA female connector provides the main L-band
output. This can also provide +24 V dc at up to 500 mA
to power an up-converter.
Table 2.16: L-band Out (Main) Connector
Item
Specification
Connector Type
50
W SMA Female
Type
Analogue
Connector designation
L-Band Out Main
Pin-outs
Centre
Signal
Screen
Ground
CAUTION…
The modulator provides dc power to drive an up-converter. Do not connect equipment to the main output
which might be damaged by dc power without protecting with a suitable dc block.
L-Band Out (Monitor)
75 W F-type female provides an L-band monitoring
output which is –30 dB relative to the main output.
Item
Specification
Connector Type
75
W F-type Female
Type
Analogue
Connector designation
L-Band Out Monitor
Pin-outs
Centre
Signal
Screen
Ground
Up-Converter Power
An LED is illuminated when the +24 V dc up-converter power on the main
output is switched on.
2.6.12 OFDM Modulator Outputs (E5715 and E5750)
IF Out 1
A 75 W BNC socket provides a 70 MHz IF output.
Table 2.17: IF Out 1 Connector
Item
Specification
Connector Type
BNC 75
W Female
Type
Analogue
Connector designation
IF Out 1
Pin-outs
Centre
Signal
Screen
Ground