Remote Gateway 9150 Installation and Administration Guide
341
January 2005 Administration
3
Enter the IP address of the TFTP server into the IP Address fields.
Note: Since the TFTP server application runs on your administration PC,
this is the IP address of the PC.
4
Click on the Browse button.
Result: The Open dialog box displays, similar to the following:
5
Ensure the Files of type drop down box shows Upgrade Files(*.UPG).
6
Navigate to the folder where the firmware file is located.
7
Select the file, and then click on the Open button.
Examples:
!
For motherboard firmware, select 9150-100.upg, and then click on the
Open button.
!
For ISDN BRI module firmware, select briv15u.upg, and then click on
the Open button.
Result: The Software Upload dialog box re-displays. The file you selected
is shown in the Uploaded File field.
8
Click on the Upload button.
Wait until the file uploads completely before entering any other commands.
The Log Report field displays a confirmation message when the upgrade is
complete.
9
Restart the Remote Gateway 9150 unit.