2 value ranges and default values – Siemens SINUMERIK 840C User Manual
Page 90

09.95
Siemens AG 2001
All Rights Reserved
6FC5197–
j
AA50
4–27
SINUMERIK 840C (IA)
4.4.2.2
Value ranges and default values
Keyword
Value range
Default value
LANGUAGE
String of max. 8 characters
“DEUTSCH”
BT_NAME
String of max. 8 characters
“SER:”
PROTLEN1
1 – 32767 (with PROTMODEDISK)
25
PROTLEN2
1 – 32767 (1–200 without
PROTMODEDISK)
25
FLUSHLEN1
0 .. 10
0
FLUSHLEN2
0 .. 10
2
FLUSHTIME
0.1 – 32767
0
PROTMASK
1 )
Special format
K = OT < 4
K > 0
PROTMASK2
Special format
T < 2
PRIO_PO
1 )
10
PRIO_RE
1 )
110
PRIO_CA
1 )
210
PRIO_PA
1 )
0,1 – < 32000
310
PRIO_PM
1 )
350
PRIO_KO
1 )
510
SYSFONT
2)
0, 1, 2
0
TFORMAT
String of max. 20 characters, see
above
“hh:mm:ss DD.MM.YY”
Language
This defines the language.
The possible languages are:
S
DEUTSCH
S
ENGLISH
S
ITALIANO
S
FRANÇAIS
S
ESPAÑOL
The default setting is DEUTSCH (upper case mandatory).
For certain software versions, SWEDISH, RUSSIAN and HUNGARIAN are
available.
SYSFONT
With SW 4.4 and higher, the character set is defined by an entry in the
Possible character set numbers:
0
Standard character set
1
Cyrillic character set
2
Character set for Slavonic languages (and Hungarian)
3
Portuguese
With SW 5.* and higher, the SYSFONT is stored in the system when selecting
the language.
4 MMC Area Diagnosis
4.4.2 Configuration file CONFIG
09.01
1) Up to SW 2 only
2) SW 4.4 and higher