6 servo trace (sw 4) – Siemens SINUMERIK 840C User Manual
Page 685

09.95
Siemens AG 2001
All Rights Reserved
6FC5197–
j
AA50
9–64
SINUMERIK 840C (IA)
9.6
SERVO trace (SW 4)
Explanation
To supplement the start-up functions “DAC output” and “Measurement function”
implemented in SW 3, SW 4 includes a trace function with the following function-
ality:
S
4 trace buffers with 2048 values
S
Output of SERVO signals with symbolic signal selection
S
Graphic representation of recorded signal waveforms
S
Various trigger conditions for starting recording
S
Pre-trigger and post-trigger settings possible
S
File functions for storing and loading trace settings and measurement curves
The SERVO trace function is integrated on the highest menu tree level of the
drive servo start-up application since the 4 trace buffers offer 4 global resources
which can be applied to any NC axis or spindle (comparable to the 4 DAC chan-
nels of the mixed I/O module).
Selection
The SERVO trace display can be called by means of softkeys Diagnosis,
Start-up and Drive servo startup.
Fig. 9.35
Explanation
The measurement parameters relevant to the trace function can be set in this
display.
The field marked “Signal” is a pure output field which indicates the measured sig-
nal selected under softkey Selection meas.signal. The text “No signal” is the
default setting.
9 Drive Servo Start-Up Application (as from SW 3)
9.6 SERVO trace (SW 4)