Siemens SINUMERIK 840C User Manual
Page 1038

07.97
12 Functional Descriptions
12.25.4 Memory configuration on control power-up
Fig. 2
Start-up/Machine data/NC MD/Memory configuration
DRAM memory configuration
General configuration
60000
Size of UMS memory
256 KB
60001
Size of part program memory
704 KB
60002
Number of IKA points
200
at 16 B
60003
Load MSD drive software
yes
0 KB
60004
Load FDD drive software
yes
0 KB
60014
Memory for MSD/FDD drive software
384 kB
60013
Number of real axes
15
16 KB
Number of block buffers per channel
61000
Channel 1
23
at 1588 B
61001
Channel 2
23
at 1588 B
61002
Channel 3
23
at 1588 B
61003
Channel 4
23
at 1588 B
61004
Channel 5
23
at 1588 B
61005
Channel 6
23
at 1588 B
Free remaining memory - DRAM data:
29 772 bytes
Free remaining memory - SRAM data:
13 552 bytes
Find
ncmemcfg
Copy
spindle
Insert
spindle
Insert
axis
Machine
Parameter
Program.
Services
Diagnosis
DRAM
data
SRAM
data
Reconfig.
memory
File
functions
Copy
axis
To ensure that this plausibility check works, the MDD fetches various information such as
•
memory requirements for one block buffer (may vary depending on SW version installed)
•
size of configurable DRAM memory, etc.
from the NC when display 2 is selected.
This information is required in order to calculate the free remaining memory and to monitor the
values entered in displays 2, 3 and 4.
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
12–263
SINUMERIK 840C (IA)